ISTA test protocols should be repeated periodically or as necessary to maintain the quality characeristics of the packaged-product on arrival. In addition, test mus be repeated whenever there is a change in the product, the package or the process. Some changes are not included in this requirements, but only if the change is not associated with potential performance in any way.

Changes in the product can include changes in:
* Design (configuration, components, accessories, etc.)
* Size/weight (dimensions, shape, mass, center of gravity, etc.)
* Materials (type, construction, fabrication, gage, etc.)

Changes in the package can include changes in:
* Configuration (individual package or unit load, container type and sub-type, style, design, interior packagin, etc.)
* Size / weight (dimensions, shape, mass, caliper, gage, etc.)
* Materials (corrugated, plastic, metal, glass, etc.)
* Components (closures, labels, straps, pallets, skids, wraps, etc.)

Changes in the process can include changes in:
* Manufacturing / assembly (vendor, lcoation, automation, etc.)
* Filling (equipment, speed, automation, etc.)
* Distribution system (parcel delivery, LTL, intermodal, etc.)

When there is any doubt as to whether a change will potentially affect performance, retesting should be done. Determining when retesting is required may involve knowing and tracking specification details of both the package and the product, such as new or changed components, materials, interior packaging, closure methods, etc.

Changing the grade of the corrugated board in the box definitely requires retest, even in those situation where carrier regulations imply "equivalence" of two grades of corrugated (such as 200 psi burst and 32 lb/in ECT grades). In many instances, corrugated from these two grading systems will be different in construction and performance and thus must be retested on a grade change. Basis weights (weight per unit area) of corrugated board constituents have been shown to be good indicators of box equivalence or change. If the basis weights change, even if the board is rated for the same performance a retest is appropriate. It is therefore strongly recommended that the measurement and documentation of basis weights in accordance with TAPPI T410 and TIP 0308-01, FEFCO (European Federation of Corrugated Board Manufacturers) Testing Method No. 10, ISO (International Organization for Standardization) EN536, ASTM D46, or other accepted industry standards accompany every packaged-product test where corrugated packaging is involved.

Retesting is also strongly recommended when distribution channels change, as this may mean a different test protocol. An example is the opening of an e-commerce business (to replace or supplement traditional retail distribution) that involves significant shipments direct to customer by small parcel carriers.

Source: ISTA Staff

 

Jul 05, 2011 - 12:57 PM

0
0
Report it

OTHER QUESTIONS NEEDING ANSWERS

Which ISTA procedure or project should I use?
Does passing an ISTA test procedure or project mean that my ...
What is the acceptance criteria for damage when testing to I...
Project 3B incline impacts are at a different velocity - why...
ISTA 3A - shock / drop testing. What are the requirements fo...
Login   |   Register