Share |

Question

Status:Closed    Asked:Nov 27, 2012 - 01:21 PM

What is / are the best test scenarios for pharma shipping in the 2-8°C for 100h?

My company has developed a new pallet size shipping container for the logstics of pharma goods in the 2-8°C zone. It withstands 100h @23°C, but we would like to do further testing. What scenarios would you recommend? We are thinking about 38°C - i.e. in extreme climates as in Dubai/ Australia and the likes. At what temperatures below 0°C would you run the test?

What would be a tough test cycel (varying the temperature) as a true shipment would undergo?

Would you include humidity? And if yes, at what levels for the respective temperatures.


best regards,


Richard

 
Do you have the same question? Follow this Question
 

Answers

A common hot scenario is 40°C at 90% RH and a common cold one is -18°C uncontrolled RH. You may want to find a ISTA CTP to consult with regarding the cycling requirements, as this is their specialty.

 

Oct 24, 2013 - 02:25 PM

0
0
Report it

OTHER QUESTIONS NEEDING ANSWERS

Any research been done on the performance of telescoping/ban...
How much recycled paperboard is acceptable in a virgin fibe...
What procedure would cover the testing of shrink wrapped uph...
HELP REQUESTED: ISTA Package Testing Near Athens, Greece
Particulate Matter Generated During Transit Testing (Medical...
1) DMF Free testing & Certification. 2) ROHS certification 3...
Login   |   Register